Analisa Perencanaan Penangkal Petir Pada Gedung Kampus Bima Sakti IST Akprind Yogyakarta

Authors

  • Syafriyuddin Institut Sains & Teknologi AKPRIND Yogyakarta
  • M Suyanto Institut Sains & Teknologi AKPRIND Yogyakarta
  • Subandi Subandi Institut Sains & Teknologi AKPRIND Yogyakarta
  • M Erfan Efendi Institut Sains & Teknologi AKPRIND Yogyakarta

Keywords:

Ground Root, Kurn R80. Lightning, soil resistance

Abstract

A natural phenomenon such as Lightning that occurs when the upper atmosphere is unstable due to the convergence of a column of warm vertical air, with a cooler mass of air above which is heated by the sun, this rising air current carries water vapor which, while filling cold air , usually condenses, causing convective storm activity, this lightning can be one of the natural causes of injury to humans or damage to electrical equipment. In planning the installation of lightning rods in the Bima Sakti IST Akprind Yogyakarta campus building using KURN R80 type with electrostatic lightning rods. For the cable carrying from the end to the control tub using the NYA cable while for grounding cable using BC cable that is connected to the ground root with a type of ground root stem which has a length of 1.5 m and a diameter of 1.5 cm. From the results of the soil resistance test, get a calculated result of 4,95 Ω, and calculated using a measuring instrument to get a result of 1.16 Ω. With the nonconventional space method in IST Akprind Yogyakarta campus building 3, the total building height up to the 27 meter final is obtained 130.4 m strike distance and 52.46 ° protection angle with a 79.45 m protection radius.

Downloads

Download data is not yet available.

Author Biographies

Syafriyuddin, Institut Sains & Teknologi AKPRIND Yogyakarta

Jurusan Teknik Elektro

 

M Suyanto, Institut Sains & Teknologi AKPRIND Yogyakarta

Jurusan Teknik Elektro

Subandi Subandi, Institut Sains & Teknologi AKPRIND Yogyakarta

Jurusan Teknik Elektro

M Erfan Efendi, Institut Sains & Teknologi AKPRIND Yogyakarta

Jurusan Teknik Elektro

References

Anderson., R. V. 2012. Lightning Discharge and Fundamentals of Lightning Protection.

Anonim., 2011. Peraturan Umum Instalasi Penangkal Petir (PUIPP) Untuk Bangunan Indonesia. Jakarta: Direktorat Penyelidikan Masalah Bangunan.

Aris, S. 2017, Perancangan Instalasi Penangkal Petir Eksternal Metoda Franklin Pada Politeknik Enjinering Indorama, Jurnal Sinergi Vol. 21, No. 3, Oktober 2017:219-230

Dadan, A. H. (2010). Optimalisasi Sistem Penangkal Petir Eksternal Menggunakan Jenis Early Streamer (Studi Kasus UPT LAGG BPPT). 37-42.

Kunal, P. 2013, Effect of Lightning on Building and Its Protection Measures, , International Journal of Engineering and Advanced Technology (IJEAT), Volume-2, Issue-6

Lambert R., X. A. (1999). Probability Density Function of the Lightning Crest Current at Ground Level Estimation of the Litghning Strike Incidence on Transmission Line. Budapest: International Confrence on Power System.

MOORE C. B, R. W. 2000. Lightning Rod Improvement Studies, Journal of Applied Meteorology, Volume 39

MOORE, C B, G. D. AULICH, AND WILLIAM RISON, 2003, The Case for Using Blunt-Tipped Lightning Rods as Strike Receptors, Journal of Applied Meteorology, Volume 42

Mustaqqim, Naser A & Arkam M 2016, Jurnal Teknologi (Sciences & Engineering) 78:5 (2016) 7–13

Purbomilihung,2008, Lightning buster, www.blogspot .com

Supartono,E.,Haryono T, Suharyanto, 2015. Application of Cone Protection and Rolling Sphere Method in External Lightning Protection Analysis on 214 Radar Tower. International Journal of Advances in Engineering & Technology, 475-481.

Syakur, A. d. 2006. Sistem Proteksi Penangkal Petir Pada Gedung Widya Puraya.

Tarımer İlhan, Kuca. B.2013, The Proposition to Safety of a Lightning Protection System for High Structures, TEM Journal, 2(4), pp. 309-313

Yen-Hong A. Chen , Kai-Jan Lin and Yu-Chu M. Li, 2017, Assesment to Efectivenees of the new early streamer emission lightning protection system, International journal on smart sensing and iteligent systems vol 10 no.1 march 2017

Zoro, R. (2013). External Lightning Protection System for Main Office Building in the Area with High Lightning Density. Journal Elsevier Procedia Technology 11 (2013) 1238 – 1243

Published

2019-12-02

How to Cite

Syafriyuddin, Suyanto, M., Subandi, S., & Efendi, M. E. (2019). Analisa Perencanaan Penangkal Petir Pada Gedung Kampus Bima Sakti IST Akprind Yogyakarta. Prosiding Seminar Nasional Teknoka, 4, E1 - E8. Retrieved from https://journal.uhamka.ac.id/index.php/teknoka/article/view/3978