Analisa Pengaruh Modifikasi Pemasangan Solenoid Valve Pada Mesin Chiller Di Kantor BKN Pusat

Authors

  • Rulan Fazriawan Universitas Muhammadiyah Prof. DR. HAMKA
  • Delvis Agusman Universitas Muhammadiyah Prof. DR. HAMKA

DOI:

https://doi.org/10.22236/teknoka.v9i1.17517

Keywords:

Solenoid valve, Mesin Chiller, Kantor BKN Pusat, Kompresor

Abstract

The air conditioning machine used at Head office BKN is air-cooled chiller machine. This chiller machine works by utilizing a vapor compression cycle. The four main components in the vapor compression cycle are: compressor, condenser, expansion valve and evaporator. The vapor compression cycle will run repeatedly as long as the chiller machine is activated. The problem with this cycle is that when the chiller machine is deactivated, the liquid refrigerant (R134A) will return to the compressor, which can cause leaks/clogging. To keep the chiller in normal condition, a solenoid valve is installed between the evaporator flow and the compressor. A solenoid valve is an electromagnetic valve that functions to control the flow of air or water. In this research, tests were carried out on chiller machines that had solenoid valves installed and those that had not been installed. The results of the research are that chiller machine compressors that have solenoid valves installed have a more stable temperature. Life time of a compressor with a stable temperature is longer

Downloads

Download data is not yet available.

References

Iskandar, Soetyono Ch & Muhsin, Z., Mesin Pendingin, Makassar: Deepublish. (2017).

Miller, Rex. and Miller, Mark R, Air Conditioning and Refrigeration, New York: McGraw-Hill. (1976).

Althouse, Andrew D. dkk., Modern Refrigeration and Air Conditioning, Illinois: Goodheart-Willcox. (2017).

Whitman, William C. dkk., Refrigeration & Air Conditioning Technology, New York: Delmar. (2012).

Vedavarz, Ali. dkk., Handbook of Heating Ventilation and Air Conditioning for Design and Implementation, New York: Industrial Press Inc. (2007).

Rizkia, Nanda Dwi. dkk., Metodologi penelitian, Bandung: Media Sains Indonesia. (2020).

Mashendra., Analisa Sistem Control Ekspansi Valve Sebagai Pengendali Temperatur Chiller, Medan: Skripsi Fakultas Teknik Universitas Muhammadiyah Sumatera Utara. (2017).

Sutrisna. Eka., Unjuk Kerja Sistem Refrigerasi dan Tata Udara AC Presisi Pada Kondisi Aliran Udara Tertutup dengan Variasi Bukaan Katup Kondenser Reheat, Depok: Skripsi Fakultas Teknik Universitas Indonesia. (2011).

Published

2024-12-27

How to Cite

Rulan Fazriawan, & Delvis Agusman. (2024). Analisa Pengaruh Modifikasi Pemasangan Solenoid Valve Pada Mesin Chiller Di Kantor BKN Pusat. Prosiding Seminar Nasional Teknoka, 9(1), 35–42. https://doi.org/10.22236/teknoka.v9i1.17517