Identifikasi Anomali dan Dampak Perbaikan Sistem Automatic Transfer Switch (ATS) terhadap Kontinuitas Pasokan Listrik di PT. PLN UP3 Tanjung Priok
Abstract
Disruptions to the Automatic Transfer Switch (ATS) system can reduce the reliability of the electricity supply, especially for priority customers. This study aims to identify anomalies occurring in the ATS system in the PT. PLN (Persero) UP3 Tanjung Priok area. The methods used include field observations, technical inspections of ATS components, switching time measurements, and estimates of unsupplied energy. Anomalies were found at three locations, namely SMU 110 Jakarta, the Water Management Public Works Sub-Department, and the Sunter Environmental Development Supervisory Agency, with the main damage occurring to the rectifier and ATS module. This damage caused automatic switching failure and interruption of the electricity supply during the repair process, resulting in a total energy loss of 330.640 kWh. After repairs were completed, the entire ATS system resumed functioning with a switching time of < 1 second, in accordance with standards. The results of this study indicate that anomalies in ATS components have a significant impact on the continuity of electricity supply, but can be effectively addressed through appropriate technical repairs.
Downloads
References
M. Ilham, A. G. Romdhon, R. P. Astutik, D. Irawan, “Journal Of Applied Smart Electrical Network And Systems (JASENS), Analisa Dan Evaluasi Kinerja ATS Pada Pelanggan Premium Tegangan Menengah di PT. PLN UP3 Gresik,” vol. 1, no. 2, pp. 56–63, 2020.
F. Sihombing, “Kajian gugatan kerugian energi listrik akibat sistem APP tidak berfungsi sesuai standar pada pelanggan khusus di PT. PLN (Persero),” Sprocket Journal of Mechanical Engineering, vol. 4, no. 2, artikel no. 897, 2022. https://jurnal.uhn.ac.id/index.php/mechanical/article/view/897
Y. Prasetyo, B. Triyono, H. N. K. Ningrum, R. J. K. Haryo, N. A. H., and W. Muchsin, “Penerapan Automatic Transfer Switch Pada Sistem Irigasi Di Desa Rejosari Kabupaten Madiun,” Jati Emas (Jurnal Aplikasi Teknik dan Pengabdian Masyarakat), vol. 4, no. 2, p. 99, Nov. 2020, doi: 10.36339/je.v4i2.313.
B. Budi Wicaksono, D. Yuliyanto Agung Prabowo, P. Studi Teknik Elektro, and I. Teknologi Adhi Tama Surabaya, “Implementasi ATS (Automatic Transfer Switch) dan AMF (Automatic Main Failure) pada Generator Set,” 2023.
M. F. Rahman, E. Purnomo, K. Rohman, M. Sa’ed, A. Shiroj, and R. Harisah, “Jar’s 1(2) Automatic Transfer Switch Kontrol Menggunakan Internet Of Thing (IOT),” 2023.
N. R. Arifin, Y. M. Dinata, and F. S. Pamungkas, “ATS (Automatic Transfer Switch) Transmission System as Power Supplier for Pahlawan Booster,” Procedia of Engineering and Life Science, vol. 7, pp. 95–98, 2024, doi: 10.21070/pels.v7i0.1577.
C. Electric, “Automatic Transfer Switch,” cnceke.com. [Online]. Available: https://www.cncele.com/ycq1b-automatic-transfer-switch-product/
F. Rahim and Buata Bangkit E., “Rancang Bangun Panel Automatic Transfer Switch (ATS) dan Automatic Main Failure (AMF),” no. september 2016, pp. 1–6, 2020.
Z. Maulia, W. Aribowo, S. I. Haryudo, dan J. Joko, “Analisis Kualitas Daya Berdasarkan Keseimbangan Beban Tiga Fasa pada Instalasi Listrik Gedung I8 Fakultas Ilmu Sosial dan Hukum Universitas Negeri Surabaya,” Jurnal Teknik Elektro (UNESA), vol. 10, no. 1, pp. 40–45, 2021.
O. Nasution, J. Napitupulu, L. Siahaan, dan Y. Ginting, “Tinjauan perbandingan pemakaian daya listrik pada bangunan industri,” Jurnal Darma Agung, vol. 30, no. 1, pp. 22–28, 2022.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Prosiding Seminar Nasional Teknoka

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

Supported by :